Leave the paper inside your timer box so that you do not mistakenly misplace it. Here are some pictures. This page is fantastic!! Any help is greatly appreciated. Yes, likely a short to ground. Check that the motor gears are still moving also, when it gets to the switch and the dial stops moving. Just some ideas. Hi Rich, is one of those wires (white?) Any advice? Hi DavyI just installed a new timer after being told by the pool inspector that the old one was dead. A switch is easier to use, so you dont have to open the clock and stick wet fingers in there, and using the breaker is also less than desirable, as they can wear out faster if used as a switch. I have an Intermatic t104. Hi Dave, my pool timers not working but when I look in the little window I do see the largest back gear turning (possibly the yellow time plate gear as that appears to be moving..yet not keeping correct time.) The timer motor cover (the oval silver box with the printing) can be pried off with a sharp screwdriver. The green tripper trips the mechanism closer to the center of the dial and the gold tripper trips the mechanism towards the outer edge of the dial. Just replace it and hope for one that isnt defective. The on/off pins are tight and pretty new stillany thoughts? I notice my pool pump was not on so I went and I hear timer running but no juice to the pool filter. Back when I was a young technician I was taught to always look for the easy things and use all my senses. If you dont think the mechanism is the issue, move onto the next step. When I put the new one on, the trippers do not work. the timer was directly plugged into a gfci and the pump directly into the timer. Lately, the timer mechanism on my old T104R does not move. everything seems to be working correctly, but i can not turn the pump on or off by tripping the mechanism. Replaced timer motor on a T10404R Now time is running fast about 2 hrs. No matter what caused the issue, there is typically an easy fix! Next step would be to inspect the wires going from timer to pump motor, or test them for continuity. I have a intermatic T101 and the clock doesnt move I replaced the old one due to burned out motor . Is there a control board, PCB in the panel that could have problems? Should I go ahead and spray it anyway? Southern Queensland Country Tourism CEO Peter Homan says water park could convert 'day trippers' to overnight visitors to Toowoomba The region's peak tourism body has claimed a widely requested water park could increase Toowoomba's appeal to a new era of visitors, as council says a park was not a priority in the coming decade. If the timer manual switch isnt jammed and freely moves into the On and Off positions, then there is either no power to the timer, the timer itself has a fault, there is an issue with the wiring or the pool pump is faulty. It seems flimsy when I click it onOnce on, it works like it should and shuts off every time. Any idea what may be causing this? Sometimes you will find the timer appears to be working, that is the clock dial is turning and you can see the gears behind the clock turning, but the pump isnt being switched on or off. A timer replacement would be required. The problem lies where the power dies, youve probably heard that before. If moving that is difficult, you could just avoid using the switch and turn the pump off with the timeclock instead, always keeping the switch on, and maybe taping the switch, to remind people not to use the switch. Hi Jeremy, I would try to pull the unit out and clean it well with compressed air and then spray with WD-40 and see if that helps. Hi Jere, that could be the timer motor failing. Resolved! Hello, I notice today that my pump wasnt running so I opened the pool breaker panel where the timer is and noticed the breaker was tripped. My intermatic timer is not turning my pool pump on. Then turn the breaker, that the time clock is connected to, off and back on again. Turn the metal bar until it contacts one of two plastic side tabs. Eldon, the breaker should not be bad, but the timeclock may be wired incorrectly. If power is coming to the timer motor, you will clearly see the gears moving through the small window. Hi Sam, check that the dial is not warped or bent, the yellow clock dial. any suggestions about how i might avoid another situation like the above would be appreciated. As an Amazon Associate we earn from qualifying purchases. I have removed the ON TRIPPER and turn the motor on at the pump and it never trips the GFCI. If unsure, the White (Neutral) wire connects to the neutral buss bar in the breaker panel, and the Black (Line) wire would connect to the circuit breaker. A 50 hz timer would run faster on 60 hz, but the housing of my replacement motor says 60 hz and it is the correct replacement model. Richard, pull the mechanism out of the box by releasing the clip at the top and inspect the copper strips and pads on the rear. I noticed that they had stopped. Above you said to connect white to A. and Black to 1what do I do with red? "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
This pool timer is waterproof, heavy-duty, and accurate. we purchased the house 5 years ago so not sure how old the timer is? Or fold the cover to one side if needed. I bought a new timer and replace the T104 timer clock. Switch the breaker off at the power board. I have a inground pool with T10003RT4 control panel. i would like to use a timer but am now afraid to try another. The 240V or the T104 models have 5 brass screws (terminals) underneath the plastic insulator cover. "logo": {
And when switched on, power to the load terminals? Hi Tom, sure you can spray some 3-in-1 or wd-40 on the motor gears, just depress the tab at 12 oclock and pop out the mechanism, to target the oil onto the gears. Push the tab on the top, and let the mechanism fall forward. These are the trippers that came with the time clock. $829,900. "name": "Davy Merino",
A wire inside the motor may be touching another wire, or the metal sides of the motor. The instructions say THIS TIMER IS NOT TO BE USED AS A POWER DISCONNECT. I look through the window of the panel and see the gears running well. the problem lies, where the power dies as they say. To check this, try to pull out the clock dial and then move it to the correct time and press it back down again. Other than a couple of weeks, we have spent fifteen years manually turning on our pump. I have the PF1202T timer on my pool. Any suggestions? Clock wont move, gear dont move at all. There is a lot of water that is making the cover sink and I dont want to keep filling the pool with water trying to get the cover up/. If it continues and cant find solution, suggest replacing timer motor, or entire mechanism. What was the fix?? 975 Telegraph Rd #103, Santa Paula, CA 93060 | MLS# V1-15365 | Redfin Intermatic time clock motors can be replaced, but unless the time clock is brand new, its best to replace the entire Intermatic mechanism. I have a 2 speed pump. On occasion the two points that are used for setting the ON and OFF times for the pool pump get damaged or loosen. There are many reasons why your pool timer may not be working. How to Repair a Pool Timer | DoItYourself.com Reddit - Dive into anything A couple of weeks in, I noticed it was not keeping time. Use Green ON tripper for T100 Series timers and the silver ON tripper is for all other models. },
on two occasions the plug from the pump almost melted and the second time the pool pump plug had to be replaced and i discontinued using the timer and disposed of it. Either that or if an older clock, the motor may be failing, or the switch mechanism worn (the part that is tripped by the tripper). Off flipper always works. The gears in mechanical timers can get damaged. If the trippers are loose, then they could slip and cause issues with the pump turning on/off at the correct times. It stays on until I turn off the circuit breaker. I not sure if this is the best timer to use. Im ready to send my back for a replacement. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
First, you need to set the time, which is good to know in case of a power outage, or daylight savings adjustments. Keeping a pool operational is expensive enough anyway, so every saving you can make helps. It is a dayton time switch model 2E259 with switch rating of 40 amps, 2 HP, 250 volts AC with clock motor rating of 250 volts and 60 cycles. Breakers go bad sometimes, after many years. It is twisted clockwise or counterclockwise until the correct current time lines up with the "Time" marker, which points directly downward at all times while the clock dial constantly turns. So what you will need to do next is to troubleshoot your Intermatic timer with a few steps. T104 mechanisms (without the box) are cheaper than buying the mech + box, but if your box is old with rusty hinges, missing gaskets, latch that wont work, it may be best to replace the box as well. This product can be controlled with your voice through Alexa-enabled devices such as Amazon Echo and Amazon Tap. You can turn the dial and then only wait a few minutes to check is the OFF tab is working. Help! It was always fine before. These clocks determine when your pool pump turns on, and how long it runs. If you loosen the hold down screw to much it could separate from the timer pin. Hello. If your pool pump timer isn't working, it's likely because of these explanations: Broken timer motor Power outage Circuit breaker problems Loose timer tags Disconnected wires Incorrect time of day Broken internal timer In this article, I'll discuss several reasons your pump's timer won't work. One morning I noticed my pool didnt automatically turn off. i have an oval pool that is closed for the winter but there ha been a problem. http://waterheatertimer.org/Tork-timers-and-manuals.html I have three outlets going out one to the pump , one for the salt system and one for the GFCI outlet. Intermatic timers are a great addition to your pool set up but they can go wrong. I have a PF1112T. However, the timer will stop around 10pm everyday and will not continue moving forward again. Gas pool heaters are one of the best additions to a pool, but they are the most high-maintenance piece of equipment on, 22,000 pool parts in stock! "primaryImageOfPage": {
I bought new trippers. Another time clock that you can plug your pump directly into, and then plug the timer into the outlet, is the 24-hr Timer https://www.intheswim.com/p/24-hour-pump-timer (currently we are out of stock, but you can find at any home or hardware store). The trippers can also get damaged. That will do it. Pool pump comes on fine with the on dog, but wont turn off. Terminals 2 and 4 are used for wires going to the load (pump). So just turn the adjustment hold down screw on the timer pin counter clockwise about a full turn and then you will be able to slide the on or off pin to the right time on the timer wheel. The clock is powered from the Line 1 terminal correct? This will disengage the dial and allow you to spin it in either direction. Now try to jiggle it on and off. Pool and Spa Expert: Mike_G2010 With the switch up it is in Auto mode. Thanks again for your help. First time pool owner, Pool timer and trippers not working properly! Sometimes the circuit breaker will trip again as soon as you reset it or even trip when the pump starts running. The pump worked perfectly before I unscrewed it. Check out our online selection of new Intermatic timer clocks at InTheSwim.com! Copyright 2022 In The Swim. I noticed that the on flipper was a little bit bent so I replaced it with new one. (For outside light timer) The one before was original to the house & I had no trouble. Should You Get a Pool Pump Timer? If you look closely (with a flashlight and your glasses! Hi Bob, you have two blacks and one neutral? 220V clocks have 5 terminals, 110V clocks have 3 terminals. Pool Pump Timer Not Working - Pool Research What do you suggest to do to get the cover up and the pillows back into position. My time clock has an ant infestation! I reset the breaker and tested the GCFI and I have 240V going in and out of the timer still but my pump isnt moving. Intermatic t101 timer troubleshooting - Ask Me Help Desk You can turn that yellow dial by hand CW to see if the trippers hit the off and on switch and to set the time on it. I have a Model T104P and have a new green on tripper attached. Hi Joe, could be time, for new timer. I just replaced an Intermatic WG1573-10D timer motor. I replaced my pool timer a couple of months ago with a Tork 1109A mechanical 240v timer. How about the GFCI outlet TEST button, is it tripped? Now, Im going to order some additional timer clips. Did somthing else maybe burnt out or what is a good troubleshooting I can do before I call an electrician. Look at the copper tabs on the back and observe the action as you flip the switch manually on and off. If the pump comes on, you definitely have power to the timer. For extra safety, shut-off the Pool breaker on the main home panel too. Sometimes the trippers get loose or damaged. OPEN TODAY, 12PM TO 3PM. Basically youre eliminating possibilities until you find the cause. But if your circuit breaker is in the on position and your pool timer clock is not rotating and the timer is not working then you will need to call a licensed electrician to replace the timer. It just stays at that time. Also be sure that the ON dog is not actually an OFF dog, and that it is tightly secured to the dial edge and pushed all the way onto the dial, and straight. by Intermatic Technical Support | Jul 25, 2022 Helpful? Hi, if you have a variable speed pump, you do not need to use the external timer anymore, but should program with the on-board pump timer. Intermatic time clocks are the workhorse of your pool equipment collection, and oftentimes outlive the equipment they control. They should be straight, if not, replace them. Hey there! Hello, newer pool guy here. Another thing you will need to troubleshoot and check is the circuit breaker for your pool timer. A qualified person would check there is power to the timer and then bypass the timer to see if the pump worked. There are simply things you can do yourself like adjust the timer pins and set the clock on the timer. Hi Alfred, I would guess that either the time dial is bent, or that the larger gear behind the dial is missing a tooth, at 10 pm, or has a bit of grit stuck in the gear at that point. Also check that the motor number is compatible with your clock model. My Intermatic Pool Timer still works like normal but, when it gets to the time set to turn pump on or off it doesnt. when the lever is in the off position the gears stop turningis this unit wired incorrectly, Natural goes to A Sometimes old power wires split or short-out. How Do You Set A Pool Pump Timer? - Pool Pro Answers During this the pump cannot be manually switched on. Like # 8 09-16-07, 03:09 PM nap New Member Join Date: May 2006 Location: north Posts: 4,162 I would shut off power to the clock while you spray, and release the tab at the top so you can spray behind the clock, and then find the nearby nest, and dig it up and add in some ant killer granular, or other method, to get the colony to move somewhere else. The position of the metal bar forces the gear next to it to turn one way or another. Is this a bad timer mechanism or loose wire? It only takes a small amount of dirt to foul up gears so look carefully.
The Ready At Moxy East Village,
Shaun Killa Biography,
San Miguel Beermen Phoenix Fuel Masters,
Articles P